Review




Structured Review

Hidex hidex amg automatic γ counter
Hidex Amg Automatic γ Counter, supplied by Hidex, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gamma+counter+hidex+amg+automatic+gamma+counter/amg+counter+hidex/pmc13267484-246-33-33
Average 86 stars, based on 1 article reviews
hidex amg automatic γ counter - by Bioz Stars, 2026-10
86/100 stars

Images

Related Articles

Radioactivity:

Article Title: Remote Neuroinflammation in Newly Diagnosed Glioblastoma Correlates with Unfavorable Clinical Outcome
Article Snippet: .. Radioactivity levels of contralateral hemispheres (n = 13 glioblastoma and n = 13 sham-injected mice) and myeloid cell enriched and depleted cell pellets were measured in a gamma counter (Hidex AMG Automatic Gamma Counter), normalized to the injected dose and the body weight, with decay correction to time of tracer injection for final activity calculations. ..

Article Title: PET imaging of microglia in Alzheimer's disease using copper-64 labeled TREM2 antibodies
Article Snippet: .. Radioactivity of the samples was measured in a gamma counter (Hidex AMG Automatic Gamma Counter, Mainz, Germany) and decay corrected to 20 h post tracer injection. .. Absolute cell counts and purity of CD11b-enriched cell pellets in each sample were acquired on a MACSQuant10 analyzer (Miltenyi Biotec, 130-105-100).

Article Title: Deciphering sources of PET signals in the tumor microenvironment of glioblastoma at cellular resolution.
Article Snippet: .. Radioactivity concentrations of cell pellets were measured in a gamma counter (Hidex AMG Automatic Gamma Counter, Mainz Germany), cross-calibrated to the activity in the whole brain, with decay correction to time of tracer injection for final activity calculations. ..

Article Title: Remote Neuroinflammation in Newly Diagnosed Glioblastoma Correlates with Unfavorable Clinical Outcome
Article Snippet: .. Radioactivity levels of contralateral hemispheres ( n = 13 glioblastoma and n = 13 sham-injected mice) and myeloid cell–enriched and –depleted cell pellets were measured in a gamma counter (Hidex AMG Automatic Gamma Counter), normalized to the injected dose and the body weight, with decay correction to time of tracer injection for final activity calculations. ..

Article Title: Functionalization of 68 Ga-Radiolabeled Nanodiamonds with Octreotide Does Not Improve Tumor-Targeting Capabilities.
Article Snippet: .. Radioactivity concentration in the organ samples was measured in a gamma counter (HIDEX AMG Automatic Gamma Counter, Turku, Finland). ..

Article Title: PIK3CA gain-of-function mutation in Schwann cells leads to severe neuropathy and aerobic glycolysis through a non-cell autonomous effect.
Article Snippet: .. The right sciatic nerves were placed in counting vials, and their weight and accumulated radioactivity were measured using a gamma counter (Hidex AMG Automatic Gamma Counter, Hidex AMG) with the following parameters: 30 s counting time, energy window: 480 to 558 keV, counting efficiency: 0.213. .. The left sciatic nerves were exposed to dedicated phosphor imaging plates (GE Healthcare) for 2.5 d. The phosphor imaging plates were scanned with a pixel size of 50 μm using the AmershamTM Typhoon IP (Cytiva).

Injection:

Article Title: Remote Neuroinflammation in Newly Diagnosed Glioblastoma Correlates with Unfavorable Clinical Outcome
Article Snippet: .. Radioactivity levels of contralateral hemispheres (n = 13 glioblastoma and n = 13 sham-injected mice) and myeloid cell enriched and depleted cell pellets were measured in a gamma counter (Hidex AMG Automatic Gamma Counter), normalized to the injected dose and the body weight, with decay correction to time of tracer injection for final activity calculations. ..

Article Title: PET imaging of microglia in Alzheimer's disease using copper-64 labeled TREM2 antibodies
Article Snippet: .. Radioactivity of the samples was measured in a gamma counter (Hidex AMG Automatic Gamma Counter, Mainz, Germany) and decay corrected to 20 h post tracer injection. .. Absolute cell counts and purity of CD11b-enriched cell pellets in each sample were acquired on a MACSQuant10 analyzer (Miltenyi Biotec, 130-105-100).

Article Title: Deciphering sources of PET signals in the tumor microenvironment of glioblastoma at cellular resolution.
Article Snippet: .. Radioactivity concentrations of cell pellets were measured in a gamma counter (Hidex AMG Automatic Gamma Counter, Mainz Germany), cross-calibrated to the activity in the whole brain, with decay correction to time of tracer injection for final activity calculations. ..

Article Title: Remote Neuroinflammation in Newly Diagnosed Glioblastoma Correlates with Unfavorable Clinical Outcome
Article Snippet: .. Radioactivity levels of contralateral hemispheres ( n = 13 glioblastoma and n = 13 sham-injected mice) and myeloid cell–enriched and –depleted cell pellets were measured in a gamma counter (Hidex AMG Automatic Gamma Counter), normalized to the injected dose and the body weight, with decay correction to time of tracer injection for final activity calculations. ..

Article Title: Preparation, radiolabeling with 99mTc and 67Ga and biodistribution studies of albumin nanoparticles coated with polymers
Article Snippet: Objective: To optimize radiolabeling with 99mTc and 67Ga of albumin nanoparticles coated with 4 differents synthetic polymers and to evaluate their stability in vivo and in vitro, as well as their biodistribution in vivo after intravenous administration.. Material and methods: The nanoparticles were prepared using albumin and NOTA-modified albumin by the desolvation met-hod and coated with 4 different polymers: HPMC, GMN2, GPM2 and GTM2.. They were purified, lyophilized and characterized.

Article Title: TREM2 expression level is critical for microglial state, metabolic capacity and efficacy of TREM2 agonism
Article Snippet: Using a MoFlo Astrios EQ cell sorter (B25982, Beckman Coulter), microglia were sorted based on their mKate2 expression into the subpopulations as described in the previous section. .. Sorted cell pellets were analysed in a gamma counter (Hidex AMG Automatic Gamma Counter) with decay correction to time of tracer injection for final activity calculations. ..

Activity Assay:

Article Title: Remote Neuroinflammation in Newly Diagnosed Glioblastoma Correlates with Unfavorable Clinical Outcome
Article Snippet: .. Radioactivity levels of contralateral hemispheres (n = 13 glioblastoma and n = 13 sham-injected mice) and myeloid cell enriched and depleted cell pellets were measured in a gamma counter (Hidex AMG Automatic Gamma Counter), normalized to the injected dose and the body weight, with decay correction to time of tracer injection for final activity calculations. ..

Article Title: Deciphering sources of PET signals in the tumor microenvironment of glioblastoma at cellular resolution.
Article Snippet: .. Radioactivity concentrations of cell pellets were measured in a gamma counter (Hidex AMG Automatic Gamma Counter, Mainz Germany), cross-calibrated to the activity in the whole brain, with decay correction to time of tracer injection for final activity calculations. ..

Article Title: Remote Neuroinflammation in Newly Diagnosed Glioblastoma Correlates with Unfavorable Clinical Outcome
Article Snippet: .. Radioactivity levels of contralateral hemispheres ( n = 13 glioblastoma and n = 13 sham-injected mice) and myeloid cell–enriched and –depleted cell pellets were measured in a gamma counter (Hidex AMG Automatic Gamma Counter), normalized to the injected dose and the body weight, with decay correction to time of tracer injection for final activity calculations. ..

Article Title: Preparation, radiolabeling with 99mTc and 67Ga and biodistribution studies of albumin nanoparticles coated with polymers
Article Snippet: Objective: To optimize radiolabeling with 99mTc and 67Ga of albumin nanoparticles coated with 4 differents synthetic polymers and to evaluate their stability in vivo and in vitro, as well as their biodistribution in vivo after intravenous administration.. Material and methods: The nanoparticles were prepared using albumin and NOTA-modified albumin by the desolvation met-hod and coated with 4 different polymers: HPMC, GMN2, GPM2 and GTM2.. They were purified, lyophilized and characterized.

Article Title: TREM2 expression level is critical for microglial state, metabolic capacity and efficacy of TREM2 agonism
Article Snippet: Using a MoFlo Astrios EQ cell sorter (B25982, Beckman Coulter), microglia were sorted based on their mKate2 expression into the subpopulations as described in the previous section. .. Sorted cell pellets were analysed in a gamma counter (Hidex AMG Automatic Gamma Counter) with decay correction to time of tracer injection for final activity calculations. ..

Concentration Assay:

Article Title: Functionalization of 68 Ga-Radiolabeled Nanodiamonds with Octreotide Does Not Improve Tumor-Targeting Capabilities.
Article Snippet: .. Radioactivity concentration in the organ samples was measured in a gamma counter (HIDEX AMG Automatic Gamma Counter, Turku, Finland). ..

Single Photon Emission Computed Tomography:

Article Title: Preparation, radiolabeling with 99mTc and 67Ga and biodistribution studies of albumin nanoparticles coated with polymers
Article Snippet: Objective: To optimize radiolabeling with 99mTc and 67Ga of albumin nanoparticles coated with 4 differents synthetic polymers and to evaluate their stability in vivo and in vitro, as well as their biodistribution in vivo after intravenous administration.. Material and methods: The nanoparticles were prepared using albumin and NOTA-modified albumin by the desolvation met-hod and coated with 4 different polymers: HPMC, GMN2, GPM2 and GTM2.. They were purified, lyophilized and characterized.



Similar Products

86
Hidex hidex amg automatic γ counter
Hidex Amg Automatic γ Counter, supplied by Hidex, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gamma+counter+hidex+amg+automatic+gamma+counter/amg+counter+hidex/pmc13267484-246-33-33
Average 86 stars, based on 1 article reviews
hidex amg automatic γ counter - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

90
Hidex gamma counter hidex amg automatic gamma counter
Gamma Counter Hidex Amg Automatic Gamma Counter, supplied by Hidex, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gamma+counter+hidex+amg+automatic+gamma+counter/gamma+counter+hidex+automatic+gamma+counter/pm40553493-172-19-21
Average 90 stars, based on 1 article reviews
gamma counter hidex amg automatic gamma counter - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Hidex automatic gamma counter hidex amg
Automatic Gamma Counter Hidex Amg, supplied by Hidex, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gamma+counter+hidex+amg+automatic+gamma+counter/gamma+counter+hidex+automatic+gamma+counter/pm39488967-199-34-36
Average 90 stars, based on 1 article reviews
automatic gamma counter hidex amg - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Hidex highly sensitive gamma counter hidex amg automatic gamma counter
Cell sorting after radiotracer injection identifies neurons as the predominant origin of [ 18 F]PI-2620 tau PET signals. a Experimental workflow of PET/MRI with subsequent cell sorting of neurons and astrocytes prior to the determination <t>of</t> <t>radioactivity</t> per isolated cell via <t>gamma</t> emission measurements and flow cytometry. b , c Comparison of radioactivity per isolated neuron and astrocyte between PS19 ( n = 5) and wild-type (WT, n = 5) mice. Each bar represents an individual animal. d Sagittal sections obtained via an MRI template showing z score images (vs. WT) of all investigated PS19 mice ( n = 5). Each image represents an individual animal. e , f Quantitative correlation between brainstem tau PET signals and radioactivity per single neuron or astrocyte. Pearson’s correlation coefficients are provided for the combined data from PS19 and WT mice (regression line with 95% confidence interval), as well as for the subset of PS19 mice. g , h Data-driven voxelwise correlation between radioactivity per single neuron or astrocyte and [ 18 F]PI-2620 tau PET images using statistical parametric mapping of the combined sample of PS19 and WT mice. Radiotracer uptake per neuron correlated with the distribution pattern of tau pathology in PS19 mice, whereas radiotracer uptake per astrocyte did not correlate with tau PET patterns. i , j Cell count and purity of isolated cells (neurons and astrocytes) as benchmark indices of the cell sorting procedure. k The increase in PET radioactivity in PS19 mice ( n = 5) compared with that in WT mice matches the increase in radioactivity determined by the number of isolated cells. The radioactivity per single cell was extrapolated from the established cell numbers in the mouse brain (71 × 10e 6 neurons, 21 × 10e 6 astrocytes)
Highly Sensitive Gamma Counter Hidex Amg Automatic Gamma Counter, supplied by Hidex, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gamma+counter+hidex+amg+automatic+gamma+counter/gamma+counter+hidex+automatic+gamma+counter/pmc11586312-96-12-15
Average 90 stars, based on 1 article reviews
highly sensitive gamma counter hidex amg automatic gamma counter - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Hidex automatic γ-counter hidex amg
Cell sorting after radiotracer injection identifies neurons as the predominant origin of [ 18 F]PI-2620 tau PET signals. a Experimental workflow of PET/MRI with subsequent cell sorting of neurons and astrocytes prior to the determination <t>of</t> <t>radioactivity</t> per isolated cell via <t>gamma</t> emission measurements and flow cytometry. b , c Comparison of radioactivity per isolated neuron and astrocyte between PS19 ( n = 5) and wild-type (WT, n = 5) mice. Each bar represents an individual animal. d Sagittal sections obtained via an MRI template showing z score images (vs. WT) of all investigated PS19 mice ( n = 5). Each image represents an individual animal. e , f Quantitative correlation between brainstem tau PET signals and radioactivity per single neuron or astrocyte. Pearson’s correlation coefficients are provided for the combined data from PS19 and WT mice (regression line with 95% confidence interval), as well as for the subset of PS19 mice. g , h Data-driven voxelwise correlation between radioactivity per single neuron or astrocyte and [ 18 F]PI-2620 tau PET images using statistical parametric mapping of the combined sample of PS19 and WT mice. Radiotracer uptake per neuron correlated with the distribution pattern of tau pathology in PS19 mice, whereas radiotracer uptake per astrocyte did not correlate with tau PET patterns. i , j Cell count and purity of isolated cells (neurons and astrocytes) as benchmark indices of the cell sorting procedure. k The increase in PET radioactivity in PS19 mice ( n = 5) compared with that in WT mice matches the increase in radioactivity determined by the number of isolated cells. The radioactivity per single cell was extrapolated from the established cell numbers in the mouse brain (71 × 10e 6 neurons, 21 × 10e 6 astrocytes)
Automatic γ Counter Hidex Amg, supplied by Hidex, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gamma+counter+hidex+amg+automatic+gamma+counter/gamma+counter+hidex+automatic+gamma+counter/pmc11445204-48-22-23
Average 90 stars, based on 1 article reviews
automatic γ-counter hidex amg - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Hidex high sensitive gamma counter hidex amg automatic gamma counter
Cell sorting after radiotracer injection identifies neurons as the predominant origin of [ 18 F]PI-2620 tau PET signals. a Experimental workflow of PET/MRI with subsequent cell sorting of neurons and astrocytes prior to the determination <t>of</t> <t>radioactivity</t> per isolated cell via <t>gamma</t> emission measurements and flow cytometry. b , c Comparison of radioactivity per isolated neuron and astrocyte between PS19 ( n = 5) and wild-type (WT, n = 5) mice. Each bar represents an individual animal. d Sagittal sections obtained via an MRI template showing z score images (vs. WT) of all investigated PS19 mice ( n = 5). Each image represents an individual animal. e , f Quantitative correlation between brainstem tau PET signals and radioactivity per single neuron or astrocyte. Pearson’s correlation coefficients are provided for the combined data from PS19 and WT mice (regression line with 95% confidence interval), as well as for the subset of PS19 mice. g , h Data-driven voxelwise correlation between radioactivity per single neuron or astrocyte and [ 18 F]PI-2620 tau PET images using statistical parametric mapping of the combined sample of PS19 and WT mice. Radiotracer uptake per neuron correlated with the distribution pattern of tau pathology in PS19 mice, whereas radiotracer uptake per astrocyte did not correlate with tau PET patterns. i , j Cell count and purity of isolated cells (neurons and astrocytes) as benchmark indices of the cell sorting procedure. k The increase in PET radioactivity in PS19 mice ( n = 5) compared with that in WT mice matches the increase in radioactivity determined by the number of isolated cells. The radioactivity per single cell was extrapolated from the established cell numbers in the mouse brain (71 × 10e 6 neurons, 21 × 10e 6 astrocytes)
High Sensitive Gamma Counter Hidex Amg Automatic Gamma Counter, supplied by Hidex, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gamma+counter+hidex+amg+automatic+gamma+counter/gamma+counter+hidex+automatic+gamma+counter/pmc11375924-186-10-13
Average 90 stars, based on 1 article reviews
high sensitive gamma counter hidex amg automatic gamma counter - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


Cell sorting after radiotracer injection identifies neurons as the predominant origin of [ 18 F]PI-2620 tau PET signals. a Experimental workflow of PET/MRI with subsequent cell sorting of neurons and astrocytes prior to the determination of radioactivity per isolated cell via gamma emission measurements and flow cytometry. b , c Comparison of radioactivity per isolated neuron and astrocyte between PS19 ( n = 5) and wild-type (WT, n = 5) mice. Each bar represents an individual animal. d Sagittal sections obtained via an MRI template showing z score images (vs. WT) of all investigated PS19 mice ( n = 5). Each image represents an individual animal. e , f Quantitative correlation between brainstem tau PET signals and radioactivity per single neuron or astrocyte. Pearson’s correlation coefficients are provided for the combined data from PS19 and WT mice (regression line with 95% confidence interval), as well as for the subset of PS19 mice. g , h Data-driven voxelwise correlation between radioactivity per single neuron or astrocyte and [ 18 F]PI-2620 tau PET images using statistical parametric mapping of the combined sample of PS19 and WT mice. Radiotracer uptake per neuron correlated with the distribution pattern of tau pathology in PS19 mice, whereas radiotracer uptake per astrocyte did not correlate with tau PET patterns. i , j Cell count and purity of isolated cells (neurons and astrocytes) as benchmark indices of the cell sorting procedure. k The increase in PET radioactivity in PS19 mice ( n = 5) compared with that in WT mice matches the increase in radioactivity determined by the number of isolated cells. The radioactivity per single cell was extrapolated from the established cell numbers in the mouse brain (71 × 10e 6 neurons, 21 × 10e 6 astrocytes)

Journal: Acta Neuropathologica

Article Title: Neuronal and oligodendroglial, but not astroglial, tau translates to in vivo tau PET signals in individuals with primary tauopathies

doi: 10.1007/s00401-024-02834-7

Figure Lengend Snippet: Cell sorting after radiotracer injection identifies neurons as the predominant origin of [ 18 F]PI-2620 tau PET signals. a Experimental workflow of PET/MRI with subsequent cell sorting of neurons and astrocytes prior to the determination of radioactivity per isolated cell via gamma emission measurements and flow cytometry. b , c Comparison of radioactivity per isolated neuron and astrocyte between PS19 ( n = 5) and wild-type (WT, n = 5) mice. Each bar represents an individual animal. d Sagittal sections obtained via an MRI template showing z score images (vs. WT) of all investigated PS19 mice ( n = 5). Each image represents an individual animal. e , f Quantitative correlation between brainstem tau PET signals and radioactivity per single neuron or astrocyte. Pearson’s correlation coefficients are provided for the combined data from PS19 and WT mice (regression line with 95% confidence interval), as well as for the subset of PS19 mice. g , h Data-driven voxelwise correlation between radioactivity per single neuron or astrocyte and [ 18 F]PI-2620 tau PET images using statistical parametric mapping of the combined sample of PS19 and WT mice. Radiotracer uptake per neuron correlated with the distribution pattern of tau pathology in PS19 mice, whereas radiotracer uptake per astrocyte did not correlate with tau PET patterns. i , j Cell count and purity of isolated cells (neurons and astrocytes) as benchmark indices of the cell sorting procedure. k The increase in PET radioactivity in PS19 mice ( n = 5) compared with that in WT mice matches the increase in radioactivity determined by the number of isolated cells. The radioactivity per single cell was extrapolated from the established cell numbers in the mouse brain (71 × 10e 6 neurons, 21 × 10e 6 astrocytes)

Article Snippet: The radioactivity concentrations of the cell pellets were measured with a highly sensitive gamma counter (Hidex AMG Automatic Gamma Counter, Mainz, Germany) are reported relative to the activity in the whole brain, with decay correction to the time of tracer injection for the final activity calculations.

Techniques: FACS, Injection, Radioactivity, Isolation, Flow Cytometry, Comparison, Cell Counting